nvmet.host_subsys.get_instance ============================== Returns instance matching `id`. If `id` is not found, Validation error is raised. Please see `query` method documentation for `options`. .. raw:: html
Query options customize the results returned by a query method. More complete documentation with examples are covered in the "Query methods" section of the TrueNAS API documentation.
No Additional PropertiesExtra options are defined on a per-endpoint basis and are described in the documentation for the associated query method.
An array of field names describing the manner in which query results should be ordered. The field names may     also have one of more of the following special prefixes: - (reverse sort direction), nulls_first: (place     any null values at the head of the results list), nulls_last: (place any null values at the tail of the     results list). 
[
        "size",
        "-devname",
        "nulls_first:-expiretime"
    ]
    An array of field names specifying the exact fields to include in the query return. The dot character .     may be used to explicitly select only subkeys of the query result. 
[
        "username",
        "Authentication.status"
    ]
    Return a numeric value representing the number of items that match the specified query-filters. 
Return the JSON object of the first result matching the specified query-filters. The query fails     if there specified query-filters return no results. 
This specifies the beginning offset of the results array. When combined with the limit query-option     it may be used to implement pagination of large results arrays. WARNING: some query methods provide     volatile results and the onus is on the developer to understand whether pagination is appropriate     for a particular query API method. 
This specifies the maximum number of results matching the specified query-filters to return. When     combined wtih the offset query-option it may be used to implement pagination of large results arrays.
WARNING: Some query methods provide volatile results and the onus is on the developer to understand whether pagination is appropriate for a particular query API method.
Force use of SQL for result filtering to reduce response time. May not work for all methods.
Unique identifier for the host-subsystem association.
NVMe-oF host that is authorized to access the subsystem.
No Additional PropertiesUnique identifier for the NVMe-oF host.
NQN of the host that will connect to this TrueNAS.
Must be at least 1 characters long
If set, the secret that the host must present when connecting.
A suitable secret can be generated using nvme gen-dhchap-key, or by using the nvmet.host.generate_key API.
Must be at least 1 characters long
If set, the secret that this TrueNAS will present to the host when the host is connecting (Bi-Directional Authentication).
A suitable secret can be generated using nvme gen-dhchap-key, or by using the nvmet.host.generate_key API.
Must be at least 1 characters long
If selected, the DH (Diffie-Hellman) key exchange built on top of CHAP to be used for authentication.
HMAC (Hashed Message Authentication Code) to be used in conjunction if a dhchap_dhgroup is selected.
NVMe-oF subsystem that the host is authorized to access.
No Additional PropertiesUnique identifier for the NVMe-oF subsystem.
Human readable name for the subsystem.
If subnqn is not provided on creation, then this name will be appended to the basenqn from     nvmet.global.config to generate a subnqn.
Must be at least 1 characters long
NVMe Qualified Name (NQN) for the subsystem.
If not provided during creation, will be auto-generated by appending the name to the basenqn     from nvmet.global.config.
Must be at least 1 characters long
Serial number assigned to the subsystem.
Any host can access the storage associated with this subsystem (i.e. no access control).
Enable Protection Information (PI) for data integrity checking.
Maximum number of queue IDs allowed for this subsystem.
IEEE Organizationally Unique Identifier for the subsystem.
If set to either True or False, then override the global ana setting from nvmet.global.config for this     subsystem only.
If null, then the global ana setting will take effect.
List of host ids which have access to this subsystem.
Only populated on query if extra.options.verbose is set.
List of namespaces ids in this subsystem.
Only populated on query if extra.options.verbose is set.
List of ports ids on which this subsystem is available.
Only populated on query if extra.options.verbose is set.