ups.update ========== Update UPS Service Configuration. .. raw:: html
Data to update the UPS configuration.
No Additional PropertiesWhether the UPS should power down after completing the shutdown sequence.
Whether to enable remote monitoring of the UPS status over the network.
Seconds to wait before warning about communication loss with UPS. null for default.
Network port for communicating with remote UPS monitoring systems.
Value must be greater or equal to 1 and lesser or equal to 65535
Seconds to wait after initiating shutdown before forcing power off. Only applies when shutdown is BATT.
Maximum seconds to wait for other systems to shutdown before continuing.
Value must be greater or equal to 0
Human-readable description of this UPS configuration.
UPS driver name that handles communication with the specific UPS hardware model.
Additional user configurations for UPS monitoring access.
Only a user with the FULL_ADMIN role may set or change this field.
Must be at most 2147483647 characters long
Unique identifier name for this UPS device within the monitoring system.
Must be at least 1 characters long
Operating mode.
* MASTER controls the UPS directly
* SLAVE monitors remotely
Password for UPS monitoring authentication (required for updates).
Must be at least 1 characters long
Username for UPS monitoring authentication.
Must be at least 1 characters long
Additional configuration options passed to the UPS driver.
Only a user with the FULL_ADMIN role may set or change this field.
Must be at most 2147483647 characters long
Additional configuration options for the UPS daemon.
Only a user with the FULL_ADMIN role may set or change this field.
Must be at most 2147483647 characters long
Serial port or device path for UPS communication.
Hostname or IP address of remote UPS server when operating in SLAVE mode.
Shutdown trigger condition: LOWBATT on low battery, BATT when on battery power.
Custom command to execute during UPS shutdown sequence. null to use the default (poweroff).
Only a user with the FULL_ADMIN role may set or change this field.
The updated UPS configuration.
No Additional PropertiesWhether the UPS should power down after completing the shutdown sequence.
Whether to enable remote monitoring of the UPS status over the network.
Unique identifier for the UPS configuration.
Seconds to wait before warning about communication loss with UPS. null for default.
Network port for communicating with remote UPS monitoring systems.
Value must be greater or equal to 1 and lesser or equal to 65535
Seconds to wait after initiating shutdown before forcing power off. Only applies when shutdown is BATT.
Maximum seconds to wait for other systems to shutdown before continuing.
Value must be greater or equal to 0
Human-readable description of this UPS configuration.
UPS driver name that handles communication with the specific UPS hardware model.
Additional user configurations for UPS monitoring access.
Only a user with the FULL_ADMIN role may set or change this field.
Must be at most 2147483647 characters long
Unique identifier name for this UPS device within the monitoring system.
Must be at least 1 characters long
Operating mode.
* MASTER controls the UPS directly
* SLAVE monitors remotely
Password for UPS monitoring authentication.
Username for UPS monitoring authentication.
Must be at least 1 characters long
Additional configuration options passed to the UPS driver.
Only a user with the FULL_ADMIN role may set or change this field.
Must be at most 2147483647 characters long
Additional configuration options for the UPS daemon.
Only a user with the FULL_ADMIN role may set or change this field.
Must be at most 2147483647 characters long
Serial port or device path for UPS communication.
Hostname or IP address of remote UPS server when operating in SLAVE mode.
Shutdown trigger condition: LOWBATT on low battery, BATT when on battery power.
Custom command to execute during UPS shutdown sequence. null to use the default (poweroff).
Only a user with the FULL_ADMIN role may set or change this field.
Complete UPS identifier including hostname for network monitoring.